1. Make Up:
CN-851M:
150 ml / L
CN-851A:
50 ml / L(46—50mL/L)
CN-851D:
4 ml / L
explaination:
Please use DI.water when make up
2. Procedure:
Temp:82
℃ (80 ~ 84 ℃);
Time:
20min (10 ~ 30 min);
Tanks
material: stainless steel 316;
Heater:
quartz or stainless steel with Teflon coating recommend use
indirect heating in water-bath
Filtration:
5~10 um PP filter core, The overflow filtering method 6~12
turn-over/hr
Vibration:
Air cylinder (up and down vibration )
Rinse:
3 times by DI. water
Other:
Auto-add device and prevent precipitation device
The deposits velocity: 6~10 µ″/ min
4.The plating layer phosphorus contain: 6% ~ 10%
5. Solution Maintenance:
1)
regular addition: (A:B:C:D= 1:1:1:0.4)
2)
analysis and adjust: according to “CP-851 Analysis specifications”
3)
Update: 4~5 M.T.O.