1、Make Up :
CC-810: 100 mL/L(80~120 mL/L)
2. Procedure :
Temp: 45 ℃ (40~50 ℃)
Time: 5min (4~6 min)
Tanks material: PVC or PP
Heater: quartz.titanium .stainless steel 316
Filtration: 5~10μm PP filter core, 3~4 turn-over/hr .
Churning: Circulation pump
Vibration: Air cylinder
Rinse: twice City water
Other: leave out
3. Solution Maintenance :
1)regular addition: 20mL/m2
2)analysis and adjust: according to “CC-810 Analysis specifications”
3)Update: 2 M.T.O.or copper ions content above 350ppm